FM 12 HELICAL COIL APPARATUS

DESCRIPTION

Helical coils are used for heating or cooling in process tanks. When a fluid flow through a curved tube, centrifugal force acting upon the various elements of fluid moving with different velocities causes secondary circulation. Secondary flow results in higher heat transfer characteristics. Further secondary flow stabilizes the laminar flow leading of a higher critical Reynolds number for transition from laminar to turbulent flow.


RANGE OF EXPERIMENTS

  • • To determine the critical Reynolds number of a fluid flowing through the coil.
  • • To determine the friction factor for flow of water through helical coil


FEATURES

  • Closed loop water circulation
  • Compact & stand alone set up
  • Stainless Steel tanks and wetted parts
  • Superb Painted structure
  • Simple to operate & maintain


UTILITIES REQUIRED

  • Electric supply 0.5 kW, 220V AC, Single Phase
  • Water supply Tap water connection ½” BSP Distilled water @ 60 liters (optional)
  • Floor Area with Drain facility


TECHNICAL SPECIFICATIONS

Product & Code Helical coil Apparatus & FM 12
Helical coil Material SS, Coil Dia 12” Turns 15, Tube dia OD 21mm, ID 17mm (approx)
Sump tank Capacity 50 Ltrs MOC SS
Flow circulation FHP capacity make Crompton Greaves / Kirloskar
Manometer For pressure drop measurement
Flow measurement Rotameter capacity 30 LPM approx.
Piping MOC GI and PVC
Control Panel Standard make on/off switch, mains indicator & fuse etc.
Overall Dimensions (L x B x H) 120 x 42 x 120 cm

The whole setup is well designed and arranged in a good quality painted structure.

error: Content is protected !!