The setup is designed to study the performance of reciprocating pump multi stage.
Set up consists of a 3 stage reciprocating pump coupled with electrical motor, supply tank, measuring tank & pipe fittings for closed loop water circulation. Pressure and Vacuum gauges are connected on delivery and suction side of pump for the purpose of measurement.
The flow rate of water is measured using measuring tank and stop watch provided.
EXPERIMENTS
To determine overall efficiency and pump efficiency of the reciprocating pump.
To plot Head vs. Discharge, Pump efficiency vs. Discharge
FEATURES
Closed loop water circulation
Compact & stand alone set up
Stainless Steel tanks and wetted parts
Superb Painted structure
Simple to operate & maintain
UTILITIES REQUIRED
Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase.
Water supply Tap water connection ½” BSP Distilled water @ 200 liters (optional)
Floor Area with drain facility
TECHNICAL DETAILS
Product & Code
Reciprocating Pump Test Rig & hm 04 AC/DC
Pump
Double acting, Single Cylinder
Capacity 1 HP, Speed 250 RPM (max.), Head 5kg/cm2 (max.)
Drive
HM 04 AC : AC motor with step cone pulley arrangement
HM 04 DC : DC motor with DC drive for variable speed
Supply Tank
Capacity 50 Ltrs. MOC SS
Measuring Tank
Capacity 30 Ltrs. MOC SS fitted with Piezometer Tube & scale