TECHNICAL DETAILS
A transparent column consisting of 12 sections. All 12 sections are connected in series by flanges with a baffle between them. The column should contain the following. (Please see section E for top and bottom section connections)
10 sections with specification as below:
Single Unit Specifications:
Internal Diameter of column (D): 25 mm (1 inch)
Height of unit (L) : 1.6D – 2.0D
Material of construction : PMMA/ any other transparent material
Column thickness : 2-3 mm (appropriate for fittings)
Baffles: (Any other arrangement to join the units which is leak proof and satisfy the requirements will also be considered)
Material Construction for Baffle : SS 304
Baffle type : Single orifice at center
Number of Baffles : 15
Orifice diameter : 0.45D (Single orifice)
Baffle thickness : 1-2 mm
Flanges:
Flange Thickness: 6- 8 mm
Flange material : Acrylic
Valves and Fittings:
Each section needs to have a valve (¼ inch) at the middle of the section to collect the sample
Other fitting as required to assemble the column
Column inlet and outlet sections:
Bottom Section: The bottom part of the column section should directly be connected to outlet of piston pump/oscillation system
Top Section: Top section of the column should be provisionally closed (¼ inch outlet to collect products and ½ inch hole for pressure gauge connection)
Sparger: Sparger assembly at bottom section to distribution of gas: 1 mm holes in sparger
Entire column with fittings should be leak proof
Supporting and mounting stand for all of units in series (entire column) without any vibrations: One side of the column should be attached with a supporting panel with proper numbering of samples valves of the each section.
Pump Specifications: to pump liquid to column
Flow Rate: 0 to 3 Liters per Minute (Adjustable) with low (0.1 HP) Horse Power; accuracy of pump (0.01 LPM). (Pump will be a fixed flow type but we can adjust flow data from 10-100% by using rotameter provided.)
Oscillation System: The oscillation to the liquid system should be given using a reciprocating piston pump housed outside the column but connected with the column with proper sealing. The system should be controlled to run at different frequencies and amplitudes in the range 0- 20 Hz (1 Hz interval) and amplitude 0-25 mm (5 mm interval)
Optional: Multi orifice Baffles (0.04D with 11 orifices (holes)
Optional: A storage tank of 100L capacity with inlet and outlet connections compatible with pump and column assembly.