HT 01 HEAT TRANSFER THROUGH COMPOSITE WALLS

Description

The setup consists of a heater sandwiched between two sets of slabs. Three types of slabs are provided on either sides of heater, which forms a composite structure. A small hand press frame is provided to ensure the perfect contact between the slabs. A variac is provided for varying the input to the heater and Digital Voltmeter and Digital Ammeter display the heat input. Heat produced by heater flows axially on both the sides. Temperature Sensors are embedded between interfaces of slabs to determine the temperature gradient. The experiment can be conducted at various values of input and calculation can be made accordingly.

EXPERIMENTS

  • To determine total thermal resistance and thermal conductivity of composite wall
  • To plot temperature gradient along composite wall structure

 

FEATURES

  • Superb Painted structure
  • Simple to operate & maintain

 

UTILITIES REQUIRED

  • Electricity Supply: 1 Phase, 220 V AC, 2 Amp.
  • Table / Floor Space for set-up support.

TECHNICAL SPECIFICATIONS

Product & Code Heat Transfer Through Composite Wall & HT 01
Slab Assembly Arranged symmetrically on both sides of heater
Slab Material: Slab Size
Cast Iron: 300 mm dia. & 20 mm thick
Bakelite: 300 mm dia. & 15 mm thick
Press Wood : 300 mm dia. & 12mm thick
Heater: Nichrome wire
Temperature Sensors RTD PT-100type (8 Nos.)
Control panel Digital Voltmeter : 0-300 Vol.
Digital Ammeter.: 0-2 Amp
Variac :0-230V, 2A
Digital Temperature Indicator: 0-200° C, with multi-channel switch, On/off switch, Mains Indicator etc
Cabinet to accommodate the slab assembly, with front window of glass/acrylic
Overall Dimensions (L X B x H) 72 x 45 x 110

Painted rigid MS structure is provided to support all parts.