HT 31 HEAT EXCHANGER SERVICE UNIT

Description

 

This experimental unit can be used to investigate and compare different heat exchanger designs. The complete experimental setup consists of two main elements service and control unit and choice of heat exchanger: Tubular heat exchanger, plate heat exchanger, shell and tube heat exchanger and jacketed vessel with stirrer and coil. Water is used as the medium.

The heat exchanger to be investigated is connected to the service unit. The hot water flows through the heat exchanger. Reversing the water connections changes the direction of flow and thus allows parallel flow or counter flow operation.

The main function of the service unit is to provide the required cold and hot water circuits. The service unit is equipped with a heated tank and pump for the hot water circuit, connections for the cold water circuit and a switch cabinet with displays and controls. A temperature controller controls the hot water temperature. The flow in the hot water and cold water circuit is adjusted using valves. The cold water circuit can be fed from the laboratory mains. The measured values can be read on digital displays. At the same time, the measured values can also be transmitted directly to a PC. The data acquisition software is included. (Optional)

FEATURES

  • Simple to operate & maintain
  • Service unit for heat exchangers
  • Software for data acquisition
  • Water connections with quick-release couplings
  • Flow adjustable using valves
  • Cold water circuit from laboratory mains
  • Required for Operation 230V, 50Hz, 1 Phase

 

EXPERIMENTS

In conjunction with a heat exchanger

  • Plotting temperature curves
  • Determining the mean heat transfer coefficient
  • Comparing different heat exchanger types

TECHNICAL DETAILS

Product & Code

Heat Exchanger Service Unit & HT 31

Pump

Power consumption: 120W, Max. Flow rate: 600L/h, Max. Head: 30m

Heater

Power output:3kW, Thermostat: 0…70°C

Hot water tank

Approx. 10L Hot water circuit with tank, heater, temperature controller, pump and protection against lack of water

Measuring ranges

Temperature: 6 x 0…100°C, Flow rate :2 x 20…250L/h

Temperature controller controls the temperature of hot water Digital displays for 6 temperature and 2 flow rate sensors

Dimensions & Weight

1.2 x 0.8 x 0.7 mm, Weight 82 kg

Painted rigid MS structure is provided to support all parts